Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: Weak Blower Output

DESCRIPTION

If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.

Symptom

Factor

  • Airflow volume is constantly low
  • Airflow volume sometimes becomes low
  • Blower motor with fan sub-assembly malfunction
  • ECO mode control of air conditioning system is enabled
  • Clogged clean air filter
  • Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins
  • No. 1 cooler thermistor malfunction
  • Aspirator not connected properly

PROCEDURE

1.

CHECK AIR CONDITIONING SYSTEM

(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed

Condition

LO → HI

  • Temperature setting: MAX COLD
  • Air outlet mode: FACE
  • A/C switch: Off

OK:

Airflow volume increases.

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit)

OK

2.

CHECK CLEAN AIR FILTER

(a) Visually check the clean air filter.

Click here

OK:

The clean air filter is not dirty or clogged.

NG

REPLACE CLEAN AIR FILTER

OK

3.

CHECK NO. 1 COOLER THERMISTOR

(a) Check the installation condition of the No. 1 cooler thermistor.

OK:

The No. 1 cooler thermistor is installed correctly.

NG

INSTALL NO. 1 COOLER THERMISTOR

OK

4.

CHECK ASPIRATOR

(a) Check the installation condition of the aspirator.

OK:

The aspirator is installed correctly.

OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY

NG

INSTALL ASPIRATOR

    READ NEXT:

     Recirculated/Fresh Air Modes Switch without User Input

    DESCRIPTION If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible. Symptom Factor Recirculation/fresh mode changes without

     Recirculated/Fresh Air Modes do not Switch

    DESCRIPTION If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.

     No Cool Air Comes Out

    DESCRIPTION If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. Symptom Factor No cool ai

    SEE MORE:

     Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure (P0ABF28)

    DESCRIPTION Refer to the description for DTC P0ABF11. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Note P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure

     Front Passenger Side Electrical Antenna Circuit Open (B27A213)

    DESCRIPTION The certification ECU (smart key ECU assembly) generates a request signal and transmits the signal to the front door outside handle assembly (for front passenger door) (electrical key antenna) at intervals of 0.25 seconds. For the front door outside handle assembly (for front passenger d

    © 2020-2025 Copyright www.tcorollacross.com PT NL