DESCRIPTION
If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor | 
|---|---|
| 
 | 
 | 
PROCEDURE
| 1. | READ VALUE USING GTS | 
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note | 
|---|---|---|---|---|
| Ambient Temperature Sensor | Thermistor assembly | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) | Actual ambient temperature displayed | Thermistor assembly circuit malfunction | 
| Tester Display | 
|---|
| Ambient Temperature Sensor | 
OK:
The value of the display does not change frequently.
| NG | .gif)  | GO TO AMBIENT TEMPERATURE DISPLAY SYSTEM | 
| 
 | 
| 2. | READ VALUE USING GTS | 
(a) Read the Data List according to the display on the GTS.
Powertrain > Engine > Data List| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note | 
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. HINT: 
 | 
| Tester Display | 
|---|
| Coolant Temperature | 
OK:
The value of the display does not change frequently.
| NG | .gif)  | GO TO COOLING SYSTEM | 
| 
 | 
| 3. | CHECK REFRIGERANT PRESSURE | 
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note | 
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32768 kPa(gauge) Max.: 32767 kPa(gauge) | Actual refrigerant pressure displayed | Refrigerant line (gas leak etc.) 
 | 
| Tester Display | 
|---|
| Regulator Pressure Sensor | 
(b) Install a manifold gauge set.
(c) Read the manifold gauge pressure when the following conditions are met.
(1) Prepare the vehicle according to the table below.
Measurement Condition:| Item | Condition | 
|---|---|
| Vehicle doors | Fully open | 
| Temperature setting | MAX COLD | 
| Blower speed | HI | 
| A/C switch | On | 
| Recirculation/fresh switch | RECIRCULATION | 
| Interior temperature | 25 to 35°C (77 to 95°F) | 
Standard Pressure:
Low pressure side
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High pressure side
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
(d) Compare the values displayed in the Data List and on the manifold gauge.
OK:
The values displayed in the Data List and on the manifold gauge match.
| OK | .gif)  | GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE) | 
| NG | .gif)  | REPLACE AIR CONDITIONER PRESSURE SENSOR | 
 Recirculated/Fresh Air Modes do not Switch
 Recirculated/Fresh Air Modes do not Switch
	 No Cool Air Comes Out
 No Cool Air Comes Out
	 Air Vent cannot be Switched
 Air Vent cannot be Switched
	 Problem Symptoms Table
 Problem Symptoms Table
	 Precaution