UTILITY
REFRIGERANT SHORTAGE CHECK USING GTS
(a) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
Measurement Condition:| Item | Condition | 
|---|---|
| A/C switch | On | 
| Ambient temperature*1 | 0 to 49°C (32 to 120°F) | 
| Blower speed | HI | 
*1: If the ambient temperature is not within the range shown, do not perform this check.
Body Electrical > Air Conditioner > Utility| Tester Display | 
|---|
| Refrigerant Gas Volume Check | 
HINT:
| Result | Amount of Refrigerant | Corrective Action | 
|---|---|---|
| Refrigerant shortage | Insufficient | 
 | 
| Refrigerant correct | Correct | - | 
REFRIGERANT PRESSURE HISTORY CLEAR
(a) Press the OFF switch.
(b) Perform the refrigerant pressure history clear according to the display on the GTS.
Body Electrical > Air Conditioner > Utility| Tester Display | 
|---|
| Refrigerant Pressure History Clear | 
A/C OPERATION LIMIT HISTORY COUNT CLEAR
(a) Press the OFF switch.
(b) Perform the A/C operation limit history count clear according to the display on the GTS.
Body Electrical > Air Conditioner > Utility| Tester Display | 
|---|
| A/C Operation Limit History Count Clear | 