DESCRIPTION
If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
|  
	 Symptom  |    Factor  |  
|---|---|
|  
		 No cool air comes out 
  |   
		
  |  
PROCEDURE
|   1.  |   
	 CHECK SWITCH INDICATOR  |  
(a) Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
OK:
All switch indicators operate normally.
|  
	 Proceed to  |  |
|---|---|
|   OK (for Dual Type)  |   
		 A  |  
|   OK (for Single Type)  |   
		 B  |  
|   NG  |   
		 C  |  
| B |  
	   |    GO TO STEP 3  |  
| C |  
	   |    GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated)  |  
 
	
  |  
|   2.  |   
	 PERFORM ACTIVE TEST USING GTS  |  
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test|  
	 Tester Display  |    Measurement Item  |   
	 Control Range  |    Diagnostic Note  |  
|---|---|---|---|
|  
		 Front Left Air Mix Damper Control Servo Motor  |   
		 No. 1 air conditioning radiator damper servo sub-assembly pulse  |   
		 Min.: 128 Max.: 384  |   
		 Operates between 165 to 257 pulses  |  
|  
		 Front Right Air Mix Damper Control Servo Motor  |   
		 No. 1 air conditioning radiator damper servo sub-assembly pulse  |   
		 Min.: 128 Max.: 384  |   
		 Operates between 255 to 347 pulses  |  
|  
	 Active Test Display  |  
|---|
|  
		 Front Left Air Mix Damper Control Servo Motor  |  
|  
	 Data List Display  |  
|---|
|  
		 Front Left Air Mix Damper Control Servo Motor Actual Pulse  |  
|  
	 Active Test Display  |  
|---|
|  
		 Front Right Air Mix Damper Control Servo Motor  |  
|  
	 Data List Display  |  
|---|
|  
		 Front Right Air Mix Damper Control Servo Motor Actual Pulse  |  
OK:
The No. 1 air conditioning radiator damper servo motor operates.
| OK |     |    INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET  |  
| NG |     |    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR  |  
|   3.  |   
	 PERFORM ACTIVE TEST USING GTS  |  
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test|  
	 Tester Display  |    Measurement Item  |   
	 Control Range  |    Diagnostic Note  |  
|---|---|---|---|
|  
		 Front Air Mix Damper Control Servo Motor  |   
		 No. 1 air conditioning radiator damper servo sub-assembly pulse  |   
		 Min.: 128 Max.: 384  |   
		 Operates between 255 to 347 pulses  |  
|  
	 Active Test Display  |  
|---|
|  
		 Front Air Mix Damper Control Servo Motor  |  
|  
	 Data List Display  |  
|---|
|  
		 Front Air Mix Damper Control Servo Motor Actual Pulse  |  
OK:
The No. 1 air conditioning radiator damper servo motor operates.
| OK |     |    INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET  |  
| NG |     |    GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR  |  
 Air Vent cannot be Switched
	
 Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)
	
 No Warm Air Comes Out
	
 Engine Oil Pressure Control Circuit Open (P06DA13)
	
 Removal