DESCRIPTION
The ECM monitors its internal operation and stores this DTC when it detects an internal malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Note | 
|---|---|---|---|---|---|
| P062F44 | Internal Control Module EEPROM Data Memory Failure | An ECM internal error (EEPROM) (1 trip detection logic). | ECM | Comes on | 
 | 
MONITOR DESCRIPTION
The ECM monitors its internal operation. If the internal operation is malfunctioning, the ECM illuminates the MIL and stores this DTC.
MONITOR STRATEGY
| Related DTCs | P062F: Internal control module EEPROM error functional | 
| Required Sensors/Components (Main) | ECM | 
| Required Sensors/Components (Related) | - | 
| Frequency of Operation | Continuous: Case 1, Case 2 Once per driving cycle: Case 3 | 
| Duration | - | 
| MIL Operation | Immediate | 
| Sequence of Operation | None | 
TYPICAL ENABLING CONDITIONS
All| Monitor runs whenever the following DTCs are not stored | None | 
| All of the following conditions are met | - | 
| Permanent fault code | Not stored | 
| OBDII system commands | Store | 
| Auxiliary battery voltage | 8 V or higher | 
| All of the following conditions are met | - | 
| Permanent fault code | Stored | 
| OBDII system commands | Clear | 
| Auxiliary battery voltage | 8 V or higher | 
| Auxiliary battery voltage | 8 V or higher | 
TYPICAL MALFUNCTION THRESHOLDS
Case 1| The following condition is met | 2 data or more | 
| One of the following conditions (a), (b) or (c) is met | More than 3 times | 
| (a) EEPROM access error | Occurred | 
| (b) Permanent fault code | Not stored | 
| (c) Permanent fault code | Not equal to commanded fault code | 
| The following condition is met | 2 data or more | 
| Either of the following conditions (a) or (b) is met | More than 3 times | 
| (a) EEPROM access error | Occurred | 
| (b) Permanent fault code | Stored | 
| Either of the following conditions is met | 1 or 2 | 
| 1. The following condition is met | 2 data or more | 
| EEPROM access error (more than 3 times) | Occurred | 
| 2. Permanent fault code data (more than 10 times) | Mismatch | 
CONFIRMATION DRIVING PATTERN
HINT:
Click here .gif) 
 
Click here .gif) 
 
HINT:
| GTS Display | Description | 
|---|---|
| NORMAL | 
 | 
| ABNORMAL | 
 | 
| INCOMPLETE | 
 | 
HINT:
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
CAUTION / NOTICE / HINT
NOTICE:
Click here .gif) 
 
Click here .gif) 
 
(Select Powertrain in Health Check and then check the time stamp data.)
Click here .gif) 
 
Click here .gif) 
 
HINT:
Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
| 1. | CLEAR DTC | 
(a) Clear the DTCs.
Powertrain > Engine > Clear DTCs(b) Turn the ignition switch off.
| 
 | 
| 2. | READ OUTPUT DTC (DTC P062F44) | 
(a) Disconnect the cable from the negative (-) auxiliary battery terminal and wait for 1 minute.
(b) Connect the cable to the negative (-) auxiliary battery terminal.
(c) Start the engine and wait 30 seconds or more.
(d) Enter the following menus.
(e) Read the DTCs.
Powertrain > Engine > Trouble Codes| Result | Proceed to | 
|---|---|
| DTCs are not output | A | 
| DTC P062F44 is output | B | 
| A | .gif)  | CHECK FOR INTERMITTENT PROBLEMS | 
| B | .gif)  | REPLACE ECM | 
 VIN Not Programmed (P063051)
 VIN Not Programmed (P063051)
	 Fuel Pump Control Module Internal Electronic Failure (P064A49)
 Fuel Pump Control Module Internal Electronic Failure (P064A49)
	 Actuator Supply Voltage "A" Circuit Short to Ground or Open (P065714)
 Actuator Supply Voltage "A" Circuit Short to Ground or Open (P065714)
	 Inspection
 Inspection
	 Software Incompatibility with Body Control Module Not Programmed (U032251,U032257)
 Software Incompatibility with Body Control Module Not Programmed (U032251,U032257)