DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunctionDESCRIPTION
|
DTC No. | Detection Item |
DTC Detection Condition |
Trouble Area | MIL |
Warning Indicate | Note |
|---|---|---|---|---|---|---|
|
P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure |
Generator inverter current sensor characteristic malfunction: The value of the total output of the U, V and W phase current sensors exceeds the threshold.*1 (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P0DFA |
|
P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent |
The value of the total output of the U, V and W phase current sensors exceeds the threshold detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored. (1 trip detection logic) |
| Does not come on |
Master Warning: Does not come on |
SAE Code: P1C69 |
HINT:
*1: Under normal conditions, the value of the total output of the U, V and W phase current sensors is approximately 0
MONITOR DESCRIPTION
If the value of the total output of the U, V and W phase current sensors exceeds a threshold, a malfunction will be detected, the motor generator control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
|
Related DTCs | P0DFA (INF P0DFA62): Signal Compare Failure |
|
Required sensors/components | Generator Phase U Current Sensor Generator Phase V Current Sensor Generator Phase W Current Sensor |
|
Frequency of operation | Continuous |
|
Duration | TMC's intellectual property |
|
MIL operation | 1 driving cycle |
|
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
|
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
|
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
|
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
|
Motor generator control ECU | DTC P0DAF (INF P0DFA62) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here
CAUTION / NOTICE / HINT
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here
NOTICE:
Click here
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
HINT:
|
Malfunction Content | System |
Relevant DTC | |
|---|---|---|---|
|
Insulation malfunction |
Hybrid control system |
P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
|
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
|
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
|
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
|
P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
|
High voltage circuit malfunction |
Hybrid control system | P0AA649 |
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
|
Malfunction Content | System |
Relevant DTC | |
|---|---|---|---|
|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
|
P0A1A49 | Generator Control Module Internal Electronic Failure | ||
|
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
|
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
|
P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | ||
|
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
|
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
|
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
|
Power source circuit malfunction |
Motor generator control system |
P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range |
|
P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
|
Communication malfunction |
Motor generator control system |
U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
|
System malfunction |
Motor generator control system |
P0A7A73 | Generator Inverter Actuator Stuck Closed |
PROCEDURE
|
1. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
|
Result | Proceed to |
|---|---|
|
OK | A |
|
NG (The connector is not connected securely.) |
B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | | CONNECT SECURELY |
| C | | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
2. | CHECK GENERATOR HIGH-VOLTAGE CIRCUIT |
Click here
HINT:
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
| NEXT | | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Generator Phase U Current Sensor Circuit Short to Battery (P0E0012,P0E0014,P0E001F,P0E0412,P0E0414,P0E041F,P0E0812,P0E0814,P0E081F)
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure (P0E0028,P0E0428,P0E0828)
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold (P0E3116,P0E3117,P0E311F)
Installation
Lost Communication with Brake System Control Module Missing Message (U012987,U014087,U015587,U111787)