DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunctionDESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
DTC No. | Detection Item |
DTC Detection Condition |
Trouble Area | MIL |
Warning Indicate | Note |
---|---|---|---|---|---|---|
P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Generator inverter current sensor U phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P0E01 |
P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Generator inverter current sensor V phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P0E05 |
P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Generator inverter current sensor W phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P0E09 |
MONITOR DESCRIPTION
If the MG ECU detects a generator inverter current sensor U, V or W phase offset malfunction, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs | P0E01 (INF P0E0028): Offset malfunction P0E05 (INF P0E0428): Offset malfunction P0E09 (INF P0E0828): Offset malfunction |
Required sensors/components | Generator Phase U Current Sensor Generator Phase V Current Sensor Generator Phase W Current Sensor |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0E01 (INF P0E0028) is not detected DTC P0E05 (INF P0E0428) is not detected DTC P0E09 (INF P0E0828) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
CAUTION / NOTICE / HINT
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here
NOTICE:
Click here
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
HINT:
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Insulation malfunction |
Hybrid control system |
P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
High voltage circuit malfunction |
Hybrid control system | P0AA649 |
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Microcomputer malfunction |
Motor generator control system | P0A1A47 |
Generator Control Module Watchdog / Safety MC Failure |
P0A1A49 | Generator Control Module Internal Electronic Failure | ||
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | ||
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
Power source circuit malfunction |
Motor generator control system | P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
Communication malfunction |
Motor generator control system |
U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
Sensor and actuator circuit malfunction |
Motor generator control system | P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
System malfunction | Motor generator control system |
P0A7A73 | Generator Inverter Actuator Stuck Closed |
PROCEDURE
1. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
A | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
B | CONNECT SECURELY |
C | REPAIR OR REPLACE HARNESS OR CONNECTOR |