Toyota Corolla Cross: Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure (P062F46)

Toyota Corolla Cross (2022-2024) Service Manual / Engine & Hybrid System / Hybrid / Battery Control / Motor Generator Control System / Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure (P062F46)

DESCRIPTION

The inverter with converter assembly monitors its internal operation and will store this DTC if it detects a malfunction of its EEPROM.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

Note

P062F46

Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure

ECU internal malfunction

(EEPROM error)

(1 trip detection logic)

Inverter with converter assembly

Comes on

Master Warning:

Comes on

SAE Code:

P062F

MONITOR DESCRIPTION

The motor generator control ECU monitors its internal operation. If the internal operation is malfunctioning, the motor generator control ECU illuminates the MIL and stores a DTC.

MONITOR STRATEGY

Related DTCs

P062F (INF P062F46): Parameter memory failure

Required sensors/components

Motor generator control ECU

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

1 driving cycle

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Motor generator control ECU

DTC P062F (INF P062F46) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here

  1. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  2. Turn the ignition switch off and wait for 2 minutes or more.
  3. Turn the ignition switch to ON and wait for 15 seconds or more. [*1]

    HINT:

    [*1]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  4. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  5. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.

CAUTION / NOTICE / HINT

NOTICE:

Be sure to check that the applicable DTC is output from the motor generator control system.

PROCEDURE

1.

CHECK DTC OUTPUT (HEALTH CHECK)

(a) Enter the following menus: System Select / Health Check.

(b) Check for DTCs.

Result

Proceed to

P062F46 is output from the motor generator control system.

A

P062F46 is output from any system other than the motor generator control system.

B

(c) Turn the ignition switch off.

A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

GO TO PERFORM DIAGNOSIS FOR RESPECTIVE SYSTEM

    READ NEXT:

     Motor Electronics Coolant Temperature Sensor Circuit Short to Ground (P0A0011,P0A0015)

    DESCRIPTION Refer to the description for DTC P0A001C. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Note P0A0

     Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range (P0A001C)

    DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs indicate that the temperature sensor value is abnormal. The cause of this malfunction may be one of the following: Area Main Malfunction Descrip

     Generator Control Module Circuit Intermittent (P0A1B1F)

    DESCRIPTION If the motor generator control ECU, which is built into the inverter with converter assembly, is reset due to a problem with the power source in the inverter, the motor generator control E

    SEE MORE:

     My Setting cannot be Recalled

    DESCRIPTION It may be possible to determine the cause of the problem by the customize setting items which are not recalled or type of registered device for which a recall is not performed. If all customize setting items are not recalled, it is suspected that the main body ECU (multiplex network body