Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On (P1CB69E)

DTC SUMMARY

MALFUNCTION DESCRIPTION

If an overvoltage malfunction occurs in the motor inverter and generator inverter, the motor generator control ECU (MG ECU) detects the malfunction and stores this DTC. The cause of this malfunction may be one of the following:

Internal inverter malfunction
  • Inverter with converter assembly internal circuit malfunction
  • Malfunction in ECU that controls the inverter

DESCRIPTION

For a description of the inverter.

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

Note

P1CB69E

Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On

Motor inverter overvoltage signal detected (circuit malfunction)

(1 trip detection logic)

  • Inverter with converter assembly
  • Wire harness or connector

Comes on

Master Warning:

Comes on

SAE Code:

P0A78

MONITOR DESCRIPTION

If the motor inverter detects a circuit malfunction, it will transmit a motor inverter overvoltage signal to the motor generator control ECU. Upon receiving this signal, the motor generator control ECU will illuminate the MIL and store a DTC.

MONITOR STRATEGY

Related DTCs

P0A78 (INF P1CB69E): OVH detection (Circuit malfunction)

Required sensors/components

Motor inverter

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

1 driving cycle

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Motor generator control ECU

DTC P0A78 (INF P1CB69E) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here

  1. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  2. Turn the ignition switch off and wait for 2 minutes or more.
  3. Turn the ignition switch to ON and wait for 5 seconds or more. [*1]
  4. Turn the ignition switch to ON (READY) and wait for 5 seconds or more. [*2]

    HINT:

    [*1] to [*2]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  5. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  6. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.

CAUTION / NOTICE / HINT

CAUTION:

Refer to the precautions before inspecting high voltage circuit.

Click here

NOTICE:

  • After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

    Click here

  • When disconnecting and reconnecting the auxiliary battery.

    HINT:

    When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

    Click here

PROCEDURE

1.

CHECK DTC OUTPUT (HYBRID CONTROL)

(a) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes

Result

Proceed to

P06881F is not output.

A

P06881F is also output.

B

(b) Turn the ignition switch off.

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

A

2.

CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click here

Result

Proceed to

OK

A

NG (The connector is not connected securely.)

B

NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)

C

A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

    READ NEXT:

     Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure (P1CFF62)

    DTC SUMMARY MALFUNCTION DESCRIPTION If there is a large difference between the reactor current sensor value and the HV battery current sensor value, a malfunction will be detected. Internal inverter m

     Transmission Fluid Temperature Sensor "C" Circuit Short to Ground (P274A11,P274A15)

    DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs are stored when the transmission fluid temperature sensor output is abnormal. The cause of this malfunction may be one of the following: Motor generator

     Transmission Fluid Temperature Sensor "C" Voltage Out of Range (P274A1C,P274A1F)

    DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs are stored when the transmission fluid temperature sensor output is abnormal. The cause of this malfunction may be one of the following: Motor generator

    SEE MORE:

     Ambient Temperature Sensor

    RemovalREMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 FRONT BUMPER ASSEMBLY - - - - 2 THERMISTOR ASSEMBLY 88790B - - - PROCEDURE 1. REMOVE FRONT BUMPER ASSEMBLY except Sport Pa

     Engine Oil Pressure Control Circuit Open (P06DA13)

    DESCRIPTION Refer to DTC P052477. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Note P06DA13 Engine Oil Pressure Control Circuit Open Open or short in oil pressure control valve assembly circuit (1 trip detection logic).

    © 2020-2024 Copyright www.tcorollacross.com