DESCRIPTION
If the cooling effect of the air conditioning system is weak, the following factors may be the cause.
|
Symptom | Factor |
|---|---|
|
|
PROCEDURE
| 1. |
PERFORM REFRIGERANT SHORTAGE CHECK |
(a) Perform the Utility according to the display on the GTS.
Body Electrical > Air Conditioner > Utility|
Tester Display |
|---|
| Refrigerant Gas Volume Check |
(b) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
Measurement Condition:|
Item | Condition |
|---|---|
|
A/C switch | On |
|
Ambient temperature* |
0 to 49°C (32 to 120°F) |
|
Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
|
Result | Amount of Refrigerant |
|---|---|
|
Refrigerant correct | Correct |
|
Refrigerant shortage |
Insufficient |
OK:
"Refrigerant correct" is displayed on the GTS.
| NG | | REPAIR REFRIGERANT LEAK |
|
| 2. |
PERFORM ACTIVE TEST USING GTS |
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test|
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
|---|---|---|---|
|
Front Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operate with ignition switch ON. |
|
Active Test Display |
|---|
|
Front Air Mix Damper Control Servo Motor |
|
Data List Display |
|---|
|
Front Air Mix Damper Control Servo Motor Actual Pulse |
OK:
The No. 1 air conditioning radiator damper servo motor operates.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |
Operation not Accepted Even If Air Conditioning Switch is Operated
Front Window Fogging
Blower Motor does not Operate
Drive Motor "B" System Circuit Current Out of Range (P0C021D)