DESCRIPTION
If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.
|
Symptom | Factor |
|---|---|
|
A/C switch indicator does not illuminate |
|
PROCEDURE
| 1. |
CHECK MALFUNCTION STATUS |
(a) Check the malfunction status of switch indicators on the air conditioning control assembly.
| Result | Proceed to |
|---|---|
|
Indicators are not always illuminated |
A |
| Indicators are not illuminated only immediately after starting the engine |
B |
| B |
| GO TO INITIALIZATION |
|
| 2. |
READ VALUE USING GTS |
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List|
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
|---|---|---|---|---|
|
Ambient Temperature Sensor |
Thermistor assembly | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (-621.81°F) |
Actual ambient temperature displayed |
Ambient temperature sensor (thermistor assembly) circuit malfunction |
|
Tester Display |
|---|
| Ambient Temperature Sensor |
OK:
The value displayed is 0°C (32°F) or higher.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System) |
Cooling is Poor
Operation not Accepted Even If Air Conditioning Switch is Operated
Front Window Fogging
Hybrid/EV Generator Circuit Current Out of Range (P1CA51D)
Control Module Communication Bus Off (U0073,U0100,U0126,U0129)