DESCRIPTION
If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.
|
Symptom | Factor |
|---|---|
|
A/C switch indicator does not illuminate |
|
PROCEDURE
| 1. |
CHECK MALFUNCTION STATUS |
(a) Check the malfunction status of switch indicators on the air conditioning control assembly.
| Result | Proceed to |
|---|---|
|
Indicators are not always illuminated |
A |
| Indicators are not illuminated only immediately after starting the engine |
B |
| B |
| GO TO INITIALIZATION |
|
| 2. |
READ VALUE USING GTS |
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List|
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
|---|---|---|---|---|
|
Ambient Temperature Sensor |
Thermistor assembly | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (-621.81°F) |
Actual ambient temperature displayed |
Ambient temperature sensor (thermistor assembly) circuit malfunction |
|
Tester Display |
|---|
| Ambient Temperature Sensor |
OK:
The value displayed is 0°C (32°F) or higher.
| OK | | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
| NG | | GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System) |
Cooling is Poor
Operation not Accepted Even If Air Conditioning Switch is Operated
Front Window Fogging
Pressure Control Solenoid "J" Circuit Short to Battery (P281F12)
Stop and Start Priority Control System