DESCRIPTION
This DTC is stored when the angle of the blind spot monitor sensor LH (B) deviates more than the allowable range from the horizontal axis.
HINT:
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
---|---|---|---|
C1AC100 |
Rear Side Radar Sensor (Module "B") Beam Axis Misalignment (Horizontal) |
When the blind spot monitor sensor deviates 5 degrees or more from the horizontal axis when the system is activated |
Blind spot monitor sensor LH (B) |
CAUTION / NOTICE / HINT
NOTICE:
Click here
If the visual inspection finds a problem, check the installation condition of the blind spot monitor sensor, and adjust the installation position of the blind spot monitor sensor as necessary.
PROCEDURE
1. |
CHECK VEHICLE CONDITION |
(a) Check the condition of the rear bumper around the blind spot monitor sensors.
HINT:
When mud, snow, ice, a sticker, etc. is covering the sensor or its surrounding area on the rear bumper, the blind spot monitor sensor may store this DTC by mistake.
Result |
Proceed to |
---|---|
A sticker, mud, snow, ice, etc. is covering the sensor or surrounding area on the rear bumper. |
A |
There are scratches or dents on the rear bumper around the sensors. |
B |
No abnormalities. |
C |
B |
GO TO STEP 3 |
C |
GO TO STEP 3 |
|
2. |
PERFORM BLIND SPOT MONITOR BEAM AXIS CONFIRMATION |
(a) Clean the rear bumper.
(b) Perform Blind Spot Monitor Beam Axis Confirmation using the GTS.
Body Electrical > Blind Spot Monitor "B" > Utility
Tester Display |
---|
BSM "B" Beam Axis Display |
Tester Display |
---|
BSM "B" Beam Axis Adjustment |
OK |
END |
NG |
REPLACE BLIND SPOT MONITOR SENSOR LH (B) Click here NOTICE: Before replacing the blind spot monitor sensor LH (B), visually check for damage to the stud bolts or area surrounding the blind spot monitor sensor LH (B). If there is any damage to the stud bolts or area surrounding the blind spot monitor sensor LH (B), perform Blind Spot Monitor Sensor Installation Condition Inspection and adjust according to the result. Click here |
3. |
CHECK INSTALLATION CONDITION |
(a) Check the installation condition of the blind spot monitor sensor LH (B).
HINT:
Click here
OK:
The blind spot monitor installation position is within the specified range.
OK |
GO TO STEP 5 |
|
4. |
ADJUST THE INSTALLATION POSITION OF THE BLIND SPOT MONITOR SENSOR LH (B) |
HINT:
Click here
|
5. |
PERFORM BLIND SPOT MONITOR BEAM AXIS CONFIRMATION |
(a) Perform Blind Spot Monitor Beam Axis Confirmation using the GTS.
Body Electrical > Blind Spot Monitor "B" > Utility
Tester Display |
---|
BSM "B" Beam Axis Display |
Tester Display |
---|
BSM "B" Beam Axis Adjustment |
OK |
END |
NG |
REPLACE BLIND SPOT MONITOR SENSOR LH (B) |