DESCRIPTION
If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
|
Symptom | Factor |
|---|---|
|
|
PROCEDURE
| 1. |
READ VALUE USING GTS (COOLANT TEMPERATURE) |
(a) Read the Data List according to the display on the GTS.
Powertrain > Engine > Data List|
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
|---|---|---|---|---|
|
Coolant Temperature | Engine coolant temperature |
Min.: -40°C (-40°F) Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up |
This is the engine coolant temperature. HINT:
|
|
Tester Display |
|---|
| Coolant Temperature |
OK:
The value of the display does not change frequently.
| NG | | GO TO COOLING SYSTEM |
|
| 2. |
PERFORM ACTIVE TEST USING GTS |
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test|
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
|---|---|---|---|
|
Front Left Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
128: Min 384: Max |
Operates between 165 to 257 pulses |
|
Front Right Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
128: Min 384: Max |
Operates between 255 to 347 pulses |
|
Active Test Display |
|---|
|
Front Left Air Mix Damper Control Servo Motor |
|
Data List Display |
|---|
|
Front Left Air Mix Damper Control Servo Motor Actual Pulse |
|
Active Test Display |
|---|
|
Front Right Air Mix Damper Control Servo Motor |
|
Data List Display |
|---|
|
Front Right Air Mix Damper Control Servo Motor Actual Pulse |
OK:
Damper servo motor is operated.
| OK | | REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY |
| NG | | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |
Precaution
Parts Location
Only Wireless Control Function is Inoperative
ECM Communication Stop Mode